{"product_id":"siemens-qbe2003-p6","title":"Siemens QBE2003-P6 - Pressure sensor for neutral and slightly aggressive liquids and gases (0...10 V) 0...6 bar","description":"\u003cdiv class=\"siemens-product-description\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"font-size: 1.05rem; line-height: 1.6; color: #1e293b; margin-bottom: 16px;\"\u003e\u003cp\u003eThe Siemens QBE2003-P6 is a high-precision relative pressure sensor engineered for continuous static and dynamic pressure measurement of neutral and mildly aggressive liquids and gases across a 0 to 6 bar range. Utilizing an advanced piezo-resistive measuring cell, it converts mechanical media pressure into a calibrated, linear DC 0...10 V signal with an ultra-fast 0.002-second response time. Its durable stainless steel and compact mechanical profile make it an essential component for demanding hydronic automation and plant monitoring systems.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv style=\"background: #f8fafc; border-left: 4px solid #00646e; padding: 12px 16px; border-radius: 4px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eRecommended Applications:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003eChilled water distribution networks and variable-speed secondary pumping control loops.\u003c\/li\u003e\n      \u003cli\u003eCommercial hydronic heating loops, boiler feed lines, and district heating substation monitoring.\u003c\/li\u003e\n      \u003cli\u003eCompressed air distribution lines, industrial coolant loops, and technical gas management.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eKey Engineering Highlights:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Piezo Sensing:\u003c\/strong\u003e Provides an ultra-fast 0.002 s time constant for instantaneous feedback during dynamic pressure shifts and water hammer events.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eStandard BMS Integration:\u003c\/strong\u003e Outputs a proportional DC 0...10 V signal and supports versatile AC 24 V or DC 12...33 V supply voltages for universal controller compatibility.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRobust Overpressure Margin:\u003c\/strong\u003e Withstands pressure spikes up to 2.5x full-scale value (15 bar overpressure limit) to prevent diaphragm damage under hydraulic transients.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBroad Media Temperature Range:\u003c\/strong\u003e Reliable operation in harsh fluid environments spanning from -15 °C up to 125 °C without signal degradation.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size: 0.9rem; color: #475569; margin-bottom: 0;\"\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation:\u003c\/strong\u003e Features a standard external G ½\" threaded connection and an industry-standard DIN EN 175301-803-A plug-in connection, allowing mounting in any physical orientation directly on pipe wells or pressure taps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-identifiers-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003ch3 style=\"margin-top: 0; margin-bottom: 12px; font-size: 1.05rem; color: #00646e;\"\u003eProduct Identification\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct No. (ASN):\u003c\/strong\u003e QBE2003-P6\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStock No. (SSN):\u003c\/strong\u003e S55720-S294\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 7612914099440\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 60 Months\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-commercial-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"margin: 0; font-size: 1.05rem; color: #00646e;\"\u003eCommercial \u0026amp; Logistics Details\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 10px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eList Price (MSRP):\u003c\/strong\u003e \u003cspan style=\"text-decoration: line-through; color: #64748b;\"\u003e€268.80\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e \u003cspan style=\"color: #0f766e; font-size: 1.15rem; font-weight: 700;\"\u003e€188.16\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.143 kg (143 g)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland (CH)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustoms HS Code:\u003c\/strong\u003e 90262020\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Order Qty (MOQ):\u003c\/strong\u003e 1 pc(s)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSales Status:\u003c\/strong\u003e \u003cspan style=\"background: #dcfce7; color: #166534; font-weight: 600; padding: 2px 6px; border-radius: 4px; font-size: 0.85rem;\"\u003eSaleable Product\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-technical-specifications\" style=\"margin-bottom: 28px;\"\u003e\n  \u003ch3 style=\"font-size: 1.15rem; color: #00646e; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable class=\"table-specs\" style=\"width: 100%; border-collapse: collapse; text-align: left; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eAnalog output, signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 0...10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eOperating voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAC 24 V, DC 12...33 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSensing element\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003ePiezo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eTime constant\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0.002 s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003ePressure connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eExternal thread\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection, electrical\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003ePlug-in connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMedium temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e-15...125 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnecting thread\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eG ½\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMax. permissible pressure\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e2.5 x scale end value (FS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMax. overpressure\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e2.5 x scale end value of measuring range15 bar\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMounting position\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAny\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasuring range, pressure\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0...6 bar, 0...600 kPa\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e32 x 101 x 52 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (Ø x L)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e24 x 101 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-documentation\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"font-size: 1.15rem; color: #00646e; margin: 0;\"\u003eDownloads \u0026amp; Technical Documentation\u003c\/h3\u003e\n    \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"font-size: 0.85rem; color: #00646e; text-decoration: underline; font-weight: 600;\"\u003eSiemens HIT Official Portal ↗\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: flex; flex-direction: column; gap: 8px;\"\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDatasheet:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure Sensors for neutral and slightly aggressive liquids and gases QBE2x03xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclarations and Certificates:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTestreport\/ Werkszeugnis QBExx, QBMxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEU Declaration of Conformity Pressure Sensor QBE2x0x QBE9x0x\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRCM Supplier's declaration QBE2xxx_QBE9xxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eUK Declaration of Conformity Pressure Sensor QBE2x0x QBE9x0x\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure sensors for liquids, gases and\u0026lt;BR\/\u0026gt;refrigerants QBE2.., QBE9..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEuropean portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAsia\/Pacific portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure sensors for neutral and slightly aggressive liquids and gases QBE2x03-P.., QBE2x03U-P..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2003-P6\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":60317216047488,"sku":"QBE2003-P6","price":166.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/6590\/3744\/files\/siemens-qbe2003-p6.jpg?v=1793796722","url":"https:\/\/fourlanosb2b.com\/products\/siemens-qbe2003-p6","provider":"Fourlanos B2B","version":"1.0","type":"link"}