{"product_id":"siemens-qbe2103-p4","title":"Siemens QBE2103-P4 - Pressure sensor for neutral and slightly aggressive liquids and gases (4...20 mA) 0...4 bar","description":"\u003cdiv class=\"siemens-product-description\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"font-size: 1.05rem; line-height: 1.6; color: #1e293b; margin-bottom: 16px;\"\u003e\u003cp\u003eThe Siemens QBE2103-P4 is a piezoresistive relative pressure sensor engineered for continuous static and dynamic pressure monitoring of neutral and slightly aggressive liquids and gases within a 0 to 4 bar (0 to 400 kPa) calibrated range. Utilizing a durable piezoresistive sensing element with a sub-2 millisecond response time, the unit transforms mechanical media pressure into a linear DC 4...20 mA two-wire current loop output. It is purpose-built for commercial HVAC, hydronic balancing, and industrial utility plant automation requiring sustained accuracy across broad fluid temperatures.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv style=\"background: #f8fafc; border-left: 4px solid #00646e; padding: 12px 16px; border-radius: 4px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eRecommended Applications:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003eCommercial chilled water loops and closed-circuit condenser water systems for pump staging and continuous head pressure monitoring.\u003c\/li\u003e\n      \u003cli\u003eDistrict heating substations and low-pressure boiler plant systems requiring robust fluid monitoring from -15 °C to 125 °C.\u003c\/li\u003e\n      \u003cli\u003eVariable primary pumping loops and potable or process liquid piping requiring reliable system pressure feedback into BMS DDC controllers.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eKey Engineering Highlights:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Signal Acquisition:\u003c\/strong\u003e Integrated piezo sensing cell delivers an ultra-fast response time of \u0026lt;2 ms, enabling precise capture of rapid pressure spikes and system transients.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eStandard Current Loop Interface:\u003c\/strong\u003e Output signal of DC 4...20 mA operating across a wide DC 7...33 V supply margin ensures noise-immune transmission over extended cable runs.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh Overpressure Safety Margin:\u003c\/strong\u003e Rated for a maximum permissible pressure of 2.5x full scale (10 bar burst protection), shielding instrumentation from hydraulic water hammer.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRugged Fluid Handling:\u003c\/strong\u003e Accommodates extreme medium operating temperatures between -15 °C and 125 °C without requiring remote siphon tubing in standard liquid lines.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size: 0.9rem; color: #475569; margin-bottom: 0;\"\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation:\u003c\/strong\u003e Features a standard external G ½\" mechanical thread connection and DIN EN 175301-803-A plug-in connector, supporting universal orientation mounting directly onto pipe tapping sleeves or gauge blocks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-identifiers-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003ch3 style=\"margin-top: 0; margin-bottom: 12px; font-size: 1.05rem; color: #00646e;\"\u003eProduct Identification\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct No. (ASN):\u003c\/strong\u003e QBE2103-P4\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStock No. (SSN):\u003c\/strong\u003e S55720-S303\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 7612914099532\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 60 Months\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-commercial-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"margin: 0; font-size: 1.05rem; color: #00646e;\"\u003eCommercial \u0026amp; Logistics Details\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 10px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eList Price (MSRP):\u003c\/strong\u003e \u003cspan style=\"text-decoration: line-through; color: #64748b;\"\u003e€268.80\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e \u003cspan style=\"color: #0f766e; font-size: 1.15rem; font-weight: 700;\"\u003e€188.16\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.138 kg (138 g)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland (CH)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustoms HS Code:\u003c\/strong\u003e 90262080\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Order Qty (MOQ):\u003c\/strong\u003e 1 pc(s)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSales Status:\u003c\/strong\u003e \u003cspan style=\"background: #dcfce7; color: #166534; font-weight: 600; padding: 2px 6px; border-radius: 4px; font-size: 0.85rem;\"\u003eSaleable Product\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-technical-specifications\" style=\"margin-bottom: 28px;\"\u003e\n  \u003ch3 style=\"font-size: 1.15rem; color: #00646e; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable class=\"table-specs\" style=\"width: 100%; border-collapse: collapse; text-align: left; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eAnalog output, signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 4...20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eOperating voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 7...33 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSensing element\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003ePiezo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eTime constant\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e\u0026lt;2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003ePressure connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eExternal thread\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection, electrical\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003ePlug-in connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMedium temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e-15...125 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnecting thread\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eG ½\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMax. permissible pressure\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e2.5 x scale end value (FS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMounting position\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAny\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasuring range, pressure\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0...4 bar, 0...400 kPa\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e32 x 101 x 52 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (Ø x L)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e24 x 101 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-documentation\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"font-size: 1.15rem; color: #00646e; margin: 0;\"\u003eDownloads \u0026amp; Technical Documentation\u003c\/h3\u003e\n    \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"font-size: 0.85rem; color: #00646e; text-decoration: underline; font-weight: 600;\"\u003eSiemens HIT Official Portal ↗\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: flex; flex-direction: column; gap: 8px;\"\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDatasheet:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure Sensors for neutral and slightly aggressive liquids and gases QBE2x03xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclarations and Certificates:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTestreport\/ Werkszeugnis QBExx, QBMxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEU Declaration of Conformity Pressure Sensor QBE2x0x QBE9x0x\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRCM Supplier's declaration QBE2xxx_QBE9xxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eUK Declaration of Conformity Pressure Sensor QBE2x0x QBE9x0x\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure sensors for liquids, gases and\u0026lt;BR\/\u0026gt;refrigerants QBE2.., QBE9..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEuropean portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAsia\/Pacific portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003ePressure sensors for neutral and slightly aggressive liquids and gases QBE2x03-P.., QBE2x03U-P..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QBE2103-P4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":60316102001024,"sku":"QBE2103-P4","price":188.16,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/6590\/3744\/files\/siemens-qbe2103-p4.jpg?v=1793794622","url":"https:\/\/fourlanosb2b.com\/products\/siemens-qbe2103-p4","provider":"Fourlanos B2B","version":"1.0","type":"link"}