{"product_id":"siemens-qfa4160d","title":"Siemens QFA4160D - Room sensor for humidity (DC 0..10V) and temperature (DC 0..10V) with calibration certificate, with display","description":"\u003cdiv class=\"siemens-product-description\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"font-size: 1.05rem; line-height: 1.6; color: #1e293b; margin-bottom: 16px;\"\u003e\u003cp\u003eThe Siemens QFA4160D is a high-accuracy room sensor designed for simultaneous measurement of relative humidity and temperature in demanding ventilation and air conditioning installations. Utilizing a high-stability capacitive sensor and a Pt1000 thin-film sensing element, the unit converts ambient conditions into independent, linearized DC 0...10 V analog outputs. Each sensor includes a factory calibration certificate and an integrated LCD display, providing verifiable measurement integrity and local process visibility for mission-critical facilities.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv style=\"background: #f8fafc; border-left: 4px solid #00646e; padding: 12px 16px; border-radius: 4px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eRecommended Applications:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003eCleanrooms, laboratories, and pharmaceutical production facilities requiring documented calibration and strict humidity control\u003c\/li\u003e\n      \u003cli\u003eHospitals, healthcare facilities, and life-science spaces requiring precision ambient monitoring\u003c\/li\u003e\n      \u003cli\u003eMuseums, archives, and high-specification commercial AHU\/VAV control zones sensitive to ambient drift\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eKey Engineering Highlights:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCertified Measurement Accuracy:\u003c\/strong\u003e Delivered with a traceable factory calibration certificate, ensuring ±2 % r.h. accuracy across the 0...100 % r.h. range and up to ±0.6 K temperature precision.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDual DC 0...10 V Proportional Outputs:\u003c\/strong\u003e Supplies separate, active DC 0...10 V signals for both relative humidity and multi-range temperature (field-selectable: 0…50 °C, -35…35 °C, or -40…70 °C).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIntegrated LCD Process Display:\u003c\/strong\u003e Features an onboard digital readout for instant field verification of environmental metrics without interfacing with the automation network.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFlexible Power \u0026amp; Enclosure Engineering:\u003c\/strong\u003e Operates on AC 24 V or DC 13.5…35 V supplies and features an IP65-rated base housing (IP40 sensor head) with a 4-wire round connector.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size: 0.9rem; color: #475569; margin-bottom: 0;\"\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation:\u003c\/strong\u003e Mounts directly to standard interior wall conduit boxes or flat wall surfaces and integrates natively via 4-wire termination with Siemens Desigo, Synco, or any standard third-party DDC controller accepting DC 0...10 V analog inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-identifiers-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003ch3 style=\"margin-top: 0; margin-bottom: 12px; font-size: 1.05rem; color: #00646e;\"\u003eProduct Identification\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct No. (ASN):\u003c\/strong\u003e QFA4160D\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStock No. (SSN):\u003c\/strong\u003e BPZ:QFA4160D\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 7612914053770\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 60 Months\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-commercial-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"margin: 0; font-size: 1.05rem; color: #00646e;\"\u003eCommercial \u0026amp; Logistics Details\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 10px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eList Price (MSRP):\u003c\/strong\u003e \u003cspan style=\"text-decoration: line-through; color: #64748b;\"\u003e€1,011.20\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e \u003cspan style=\"color: #0f766e; font-size: 1.15rem; font-weight: 700;\"\u003e€707.84\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.183 kg (183 g)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland (CH)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustoms HS Code:\u003c\/strong\u003e 90258040\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Order Qty (MOQ):\u003c\/strong\u003e 1 pc(s)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSales Status:\u003c\/strong\u003e \u003cspan style=\"background: #dcfce7; color: #166534; font-weight: 600; padding: 2px 6px; border-radius: 4px; font-size: 0.85rem;\"\u003eSaleable Product\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-technical-specifications\" style=\"margin-bottom: 28px;\"\u003e\n  \u003ch3 style=\"font-size: 1.15rem; color: #00646e; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable class=\"table-specs\" style=\"width: 100%; border-collapse: collapse; text-align: left; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSignal output humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 0...10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSignal output temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 0...10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eOperating voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAC 24 V, DC 13.5…35 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSensing element, temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003ePt1000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasuring range, temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0…50 °C, -35…35 °C, -40…70 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasurement range humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0…100 % r.h.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasurement accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAt 15…35 °C: ±0.6 K, At 40…70 °C: ±0.8 K23 % r.h., 0…100 % r.h.: ±2 % r.h.±2 % r.h.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eTime constant\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eHumidity: 20 s, Temperature: 510 s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection, electrical\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eRound connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e4-wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eAnalog output, signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 0...10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eLCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eColor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eGray\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDegree of protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eIP65 \/ IP40\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e80 x 144 x 39 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-documentation\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"font-size: 1.15rem; color: #00646e; margin: 0;\"\u003eDownloads \u0026amp; Technical Documentation\u003c\/h3\u003e\n    \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"font-size: 0.85rem; color: #00646e; text-decoration: underline; font-weight: 600;\"\u003eSiemens HIT Official Portal ↗\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: flex; flex-direction: column; gap: 8px;\"\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDatasheet:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRoom_sensor QFA41..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclarations and Certificates:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTestreport\/ Werkszeugnis  (T + RF Sensors)\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEU Declaration of Conformity QFA41xx\/AQF41xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRCM Supplier's  Declaration QPA..\/QPM..\/QFA..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eUK Declaration of conformity for QFA41xx\/AQF41xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTest report MTBF for QFM.., QFA..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRoom sensor for relative humidity and temperature\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEPD Type II with LCA - Wired Sensors - Room Sensors QAA..., QFA..., QPA...\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEuropean portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAsia\/Pacific portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAmericas portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFA4160D\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":60316185624960,"sku":"QFA4160D","price":707.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/6590\/3744\/files\/siemens-qfa4160d_aa0b8e4e-ab8e-4751-a395-77a1bc42108a.jpg?v=1793794678","url":"https:\/\/fourlanosb2b.com\/products\/siemens-qfa4160d","provider":"Fourlanos B2B","version":"1.0","type":"link"}