{"product_id":"siemens-qfm4171","title":"Siemens QFM4171 - Duct sensor for humidity (4...20 mA) and temperature (4...20 mA) with calibration certificate","description":"\u003cdiv class=\"siemens-product-description\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"font-size: 1.05rem; line-height: 1.6; color: #1e293b; margin-bottom: 16px;\"\u003e\u003cp\u003eThe Siemens QFM4171 is an industrial-grade duct sensor engineered for continuous, high-precision measurement of relative humidity (0...100% r.h.) and temperature across configurable ranges. It delivers dual DC 4...20 mA analog signals designed for noise-immune transmission over extended cable distances to supervisory building automation systems. Delivered with an individual calibration certificate and housed in an IP65-rated enclosure, it provides verifiable measurement accuracy for demanding ventilation and process environments.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv style=\"background: #f8fafc; border-left: 4px solid #00646e; padding: 12px 16px; border-radius: 4px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eRecommended Applications:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003eCritical cleanroom, laboratory, and pharmaceutical HVAC environments requiring documented calibration traceability\u003c\/li\u003e\n      \u003cli\u003eSupply, exhaust, and recirculation air ducts in high-specification commercial Air Handling Units (AHUs)\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing and storage facilities requiring tight humidity control and washdown-tolerant IP65 protection\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eKey Engineering Highlights:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFactory-Certified Precision:\u003c\/strong\u003e Delivered with an individual calibration certificate verifying high-precision performance (±2% r.h. across 0...100% r.h. and up to ±0.6 K temperature accuracy).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDual 4...20 mA Current Loops:\u003c\/strong\u003e Provides robust, interference-resistant analog outputs for both process variables, operating reliably on DC 13.5…35 V supply power.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSelectable Temperature Spans:\u003c\/strong\u003e Offers field-selectable temperature measurement ranges (0…50 °C, -35…35 °C, and -40…70 °C) to match specific process requirements.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAdjustable Duct Insertion:\u003c\/strong\u003e Includes a versatile mounting flange allowing variable immersion probe depths from 90 mm to 206 mm for optimal placement in the airstream.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size: 0.9rem; color: #475569; margin-bottom: 0;\"\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation:\u003c\/strong\u003e Mounts directly to supply or extract air ducts via the included adjustable immersion flange and interfaces seamlessly with any DDC or PLC controller supporting standard two-wire 4...20 mA current inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-identifiers-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003ch3 style=\"margin-top: 0; margin-bottom: 12px; font-size: 1.05rem; color: #00646e;\"\u003eProduct Identification\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct No. (ASN):\u003c\/strong\u003e QFM4171\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStock No. (SSN):\u003c\/strong\u003e BPZ:QFM4171\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 4047625020071\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 60 Months\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-commercial-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"margin: 0; font-size: 1.05rem; color: #00646e;\"\u003eCommercial \u0026amp; Logistics Details\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 10px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eList Price (MSRP):\u003c\/strong\u003e \u003cspan style=\"text-decoration: line-through; color: #64748b;\"\u003e€947.40\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e \u003cspan style=\"color: #0f766e; font-size: 1.15rem; font-weight: 700;\"\u003e€663.18\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.185 kg (185 g)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Switzerland (CH)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustoms HS Code:\u003c\/strong\u003e 90258040\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Order Qty (MOQ):\u003c\/strong\u003e 1 pc(s)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSales Status:\u003c\/strong\u003e \u003cspan style=\"background: #dcfce7; color: #166534; font-weight: 600; padding: 2px 6px; border-radius: 4px; font-size: 0.85rem;\"\u003eSaleable Product\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-technical-specifications\" style=\"margin-bottom: 28px;\"\u003e\n  \u003ch3 style=\"font-size: 1.15rem; color: #00646e; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable class=\"table-specs\" style=\"width: 100%; border-collapse: collapse; text-align: left; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSignal output humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 4...20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eSignal output temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 4...20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eOperating voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 13.5…35 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasuring range, temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0…50 °C, -35…35 °C, -40…70 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasurement range humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0…100 % r.h.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasurement accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAt 15…35 °C: ±0.6 K, At 40…70 °C: ±0.8 K23 % r.h., 0…100 % r.h.: ±2 % r.h.±2 % r.h.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eTime constant\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eHumidity: 20 s, Air v=2 m\/s: 210 s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eImmersion length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e90…206 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eNo display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection, electrical\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eRound connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eType of fixing\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eFlange\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDegree of protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e80 x 117 x 39 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-documentation\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"font-size: 1.15rem; color: #00646e; margin: 0;\"\u003eDownloads \u0026amp; Technical Documentation\u003c\/h3\u003e\n    \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"font-size: 0.85rem; color: #00646e; text-decoration: underline; font-weight: 600;\"\u003eSiemens HIT Official Portal ↗\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: flex; flex-direction: column; gap: 8px;\"\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDatasheet:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct_sensor QFM41..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclarations and Certificates:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTestreport\/ Werkszeugnis  (T + RF Sensors)\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEU Declaration of Concormity  QFM41xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRCM Supplier's  declaration QAMx1... \/ QFM...\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eUK Declaration of conformity for QFM41xx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTest report MTBF for QFM.., QFA..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct sensor for relative humidity and temperature\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEPD Type III - Wired Sensors - Duct and Immersion Sensors QAC…, QAE…, QAM…,QBM…,QFM…\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEPD Type II with LCA - Wired Sensors - Duct and Immersion Sensors QAC…, QAE…, QAM…, QBM…, QFM…\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEuropean portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAsia\/Pacific portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAmericas portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct sensor for rel. humidity \/ temperature QFM.., with 0…5 V output\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct sensor for rel. humidity \/ temperature QFM.., w\/o 0…5 V output\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QFM4171\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":60316173500800,"sku":"QFM4171","price":587.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/6590\/3744\/files\/siemens-qfm4171.jpg?v=1793794671","url":"https:\/\/fourlanosb2b.com\/products\/siemens-qfm4171","provider":"Fourlanos B2B","version":"1.0","type":"link"}