{"product_id":"siemens-qpm2180","title":"Siemens QPM2180 - Duct air quality sensor CO\u003cSUB\u003e2\u003c\/SUB\u003e+temperature (passiv)","description":"\u003cdiv class=\"siemens-product-description\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"font-size: 1.05rem; line-height: 1.6; color: #1e293b; margin-bottom: 16px;\"\u003e\u003cp\u003eThe Siemens QPM2180 is a duct-mounted air quality sensor engineered to measure carbon dioxide (CO₂) concentration and passive temperature within commercial ventilation systems. Utilizing optical infrared absorption (NDIR) technology, it accurately evaluates CO₂ levels across a 0 to 2000 ppm range to optimize demand-controlled ventilation (DCV). Designed for extract and supply air ducts, the unit operates reliably in air velocities up to 10 m\/s to ensure energy-efficient building air exchange.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv style=\"background: #f8fafc; border-left: 4px solid #00646e; padding: 12px 16px; border-radius: 4px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eRecommended Applications:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003eDemand-controlled ventilation (DCV) loops in central air handling units (AHUs) serving schools, conference rooms, and commercial offices.\u003c\/li\u003e\n      \u003cli\u003eReturn and extract air monitoring for commercial building automation systems (BAS) to regulate outdoor air dampers.\u003c\/li\u003e\n      \u003cli\u003eCombined IAQ and thermal monitoring in variable air volume (VAV) supply air streams to meet ASHRAE 62.1 fresh air standards.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #00646e; font-size: 0.95rem; display: block; margin-bottom: 6px;\"\u003eKey Engineering Highlights:\u003c\/strong\u003e\n    \u003cul style=\"margin: 0; padding-left: 18px; color: #334155; font-size: 0.9rem; line-height: 1.5;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMulti-Signal Output Flexibility:\u003c\/strong\u003e Delivers field-selectable analog outputs of DC 0...10 V, DC 0...5 V, or DC 4...20 mA for CO₂, alongside an integrated passive temperature element.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAdjustable Immersion Depth:\u003c\/strong\u003e Features a versatile 100 to 165 mm probe immersion length for precise centerline positioning within diverse duct dimensions.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eWide Aerodynamic Range:\u003c\/strong\u003e Engineered to withstand and measure accurately within duct air velocities reaching up to 10 m\/s without signal degradation.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBroad Power Supply Tolerance:\u003c\/strong\u003e Operates efficiently on AC 24 V or DC 15...35 V power supplies with a low nominal power consumption of 2 VA.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size: 0.9rem; color: #475569; margin-bottom: 0;\"\u003e\u003cstrong\u003eCompatibility \u0026amp; Installation:\u003c\/strong\u003e Mounts directly to sheet metal ductwork via an adjustable immersion mounting flange, connecting to standard DDC inputs and building automation systems via robust screw terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-identifiers-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003ch3 style=\"margin-top: 0; margin-bottom: 12px; font-size: 1.05rem; color: #00646e;\"\u003eProduct Identification\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct No. (ASN):\u003c\/strong\u003e QPM2180\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStock No. (SSN):\u003c\/strong\u003e S55720-S124\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGTIN \/ EAN:\u003c\/strong\u003e 7612914075963\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 60 Months\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-commercial-card\" style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"margin: 0; font-size: 1.05rem; color: #00646e;\"\u003eCommercial \u0026amp; Logistics Details\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 10px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eList Price (MSRP):\u003c\/strong\u003e \u003cspan style=\"text-decoration: line-through; color: #64748b;\"\u003e€580.80\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrice:\u003c\/strong\u003e \u003cspan style=\"color: #0f766e; font-size: 1.15rem; font-weight: 700;\"\u003e€406.56\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.198 kg (198 g)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e China (CN)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustoms HS Code:\u003c\/strong\u003e 90271010\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum Order Qty (MOQ):\u003c\/strong\u003e 1 pc(s)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSales Status:\u003c\/strong\u003e \u003cspan style=\"background: #dcfce7; color: #166534; font-weight: 600; padding: 2px 6px; border-radius: 4px; font-size: 0.85rem;\"\u003eSaleable Product\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-technical-specifications\" style=\"margin-bottom: 28px;\"\u003e\n  \u003ch3 style=\"font-size: 1.15rem; color: #00646e; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003ctable class=\"table-specs\" style=\"width: 100%; border-collapse: collapse; text-align: left; font-size: 0.95rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eOperating voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eAC 24 V, DC 15...35 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003ePower consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e2 VA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eImmersion length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e100...165 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eAnalog output, signal\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eDC 0...10 V, DC 0...5 V, DC 4...20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eMeasuring range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e0...2000 ppm CO₂\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003ePermissible air velocity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e10 m\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eAmbient temperature, operation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e-5...45 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eConnection, electrical\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003eScrew terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #ffffff; border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px 12px; font-weight: 600; color: #475569; width: 45%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px 12px; color: #1e293b;\"\u003e80 x 88 x 278 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"siemens-documentation\" style=\"margin-bottom: 24px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: space-between; border-bottom: 2px solid #00646e; padding-bottom: 6px; margin-bottom: 12px; flex-wrap: wrap; gap: 8px;\"\u003e\n    \u003ch3 style=\"font-size: 1.15rem; color: #00646e; margin: 0;\"\u003eDownloads \u0026amp; Technical Documentation\u003c\/h3\u003e\n    \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"font-size: 0.85rem; color: #00646e; text-decoration: underline; font-weight: 600;\"\u003eSiemens HIT Official Portal ↗\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cul style=\"list-style: none; padding-left: 0; margin: 0; display: flex; flex-direction: column; gap: 8px;\"\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDatasheet:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct Air Quality Sensors QPM21..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclarations and Certificates:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTestreport\/ Werkszeugnis  (T + RF Sensors)\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEU Declaration of Conformity QPMxxxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eRCM Supplier's  Declaration QPA..\/QPM..\/QFA..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eUK Declaration of conformity for QPMxxxx\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eDeclaration of conformity:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eTest report MTBF for QP..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eEnvironmental Documents:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct Air Quality Sensor\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eEuropean portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #059669; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003eEXTERNAL\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eCAD and BIM product data (PartCommunity):\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eAsia\/Pacific portfolio: click here for further information\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eSensor mounting for QPA.., QPM..\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"display: flex; align-items: center; justify-content: space-between; padding: 10px 14px; background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; flex-wrap: wrap; gap: 8px;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; gap: 10px;\"\u003e\n        \u003cspan style=\"background: #dc2626; color: #ffffff; font-size: 0.75rem; font-weight: 700; padding: 2px 6px; border-radius: 4px;\"\u003ePDF\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color: #1e293b;\"\u003eMounting instruction:\u003c\/strong\u003e \u003cspan style=\"color: #475569;\"\u003eDuct air quality sensor CO2\/ temperature \/ rel. Humidity \/ VOC QPM11..., QPM21...\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003ca href=\"https:\/\/hit.sbt.siemens.com\/RWD\/App\/Main?RC=HQEU\u0026amp;lang=en\u0026amp;MODULE=Catalog\u0026amp;ACTION=ShowProduct\u0026amp;KEY=BPZ:QPM2180\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display: inline-block; padding: 5px 12px; background: #00646e; color: #ffffff; text-decoration: none; border-radius: 4px; font-size: 0.85rem; font-weight: 600; white-space: nowrap;\"\u003eView on Siemens HIT ↗\u003c\/a\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":60317213098368,"sku":"QPM2180","price":360.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/6590\/3744\/files\/siemens-qpm2180.jpg?v=1793796660","url":"https:\/\/fourlanosb2b.com\/products\/siemens-qpm2180","provider":"Fourlanos B2B","version":"1.0","type":"link"}