Product Details & Technical Specifications
The Belimo 22DC-13 is an original Swiss-engineered HVAC component (Duct sensor CO₂ active, 0...5 V, 0...10 V, 4...20 mA, Probe length 150 mm, Probe diameter 19.5 mm) in the Belimo Duct Sensors (Air) series, designed for commercial building automation, hydronic control, and air-handling systems.
Key Technical Highlights:
- Voltage AC/DC: AC/DC 24 V
- Electrical connection: Terminals
- Measured values: CO₂
- Output signal: 0...5 V, 0...10 V, 4...20 mA
- Measuring range CO₂: Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm
Product Identification
- Brand: Belimo
- Part No. (SKU): 22DC-13
- Department: Sensors
- Category: Duct Sensors (Air)
- Warranty: 5 Years Standard Manufacturer Warranty
Commercial & Logistics Details
- List Price (MSRP): €378.00 (EXW)
- Trade Price: €227,02
- Manufacturer HQ: Switzerland (CH)
- Minimum Order Qty (MOQ): 1 pc(s)
- Sales Status: Saleable Product
Technical Specifications
| Voltage AC/DC | AC/DC 24 V |
| Electrical connection | Terminals |
| Measured values | CO₂ |
| Output signal | 0...5 V, 0...10 V, 4...20 mA |
| Measuring range CO₂ | Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm |
| Measuring range temperature | 0...50°C [32...122°F] |
| Output Voltage [Range] | 1 x 0...5 V, 0...10 V, min. resistance 10 kΩ (Type 22DC-13)2 x 0...5 V, 0...10 V, min. resistance 10 kΩ (Type 22DTC-13) |
| Output Current [Range] | 1x 4...20 mA, max. resistance 500 Ω (22DC-13)2x 4...20 mA, max. resistance 500 Ω (22DTC-13) |
| Output signal active note | Output 0...5/10 V with Jumper adjustable |
| Probe length | 150 mm |
Downloads & Technical Documentation
Belimo Official Portal ↗-
PDFDownload PDF ↗Technical data sheet – 22D..-13
-
PDFDownload PDF ↗Installation instructions – 22DC..-.. / 22DT..-..
-
PDFDownload PDF ↗Installation instructions – 22DC..-.. / 22DT..-.. flex conduit
-
PDFDownload PDF ↗EU Declaration of Conformity – 22DC-13
-
PDFDownload PDF ↗Environmental Declaration – 22DC../22DTC../22DTM../22DCV../22DCM../22DCK..
-
PDFDownload PDF ↗Brochure – Belimo sensors and meters
-
PDFDownload PDF ↗Flyer – CO2 measured values below 400 ppm - Error or reality ?
-
PDFDownload PDF ↗Manual – Sensor installation
-
PDFDownload PDF ↗Reference – AR Bygg, Sweden
-
PDFDownload PDF ↗Reference – Emch+Berger ImmoConsult AG, Switzerland
-
PDFDownload PDF ↗Reference – HUG AG, Switzerland
-
PDFDownload PDF ↗Reference – Hagl GmbH, Germany
-
PDFDownload PDF ↗Reference – High-rise building Tscharnergut Bern, Switzerland
-
PDFDownload PDF ↗Reference – Motta hut Lenzerheide, Switzerland
-
PDFDownload PDF ↗Reference – Phoenix Contact, Switzerland
-
PDFDownload PDF ↗Reference – Scott Sports Givisiez, Switzerland
-
PDFDownload PDF ↗Reference – Stadler Rail St. Margrethen, Switzerland
-
PDFDownload PDF ↗Reference – UTEK, Italy
-
PDFDownload PDF ↗Reference – University Hospital Zurich, Switzerland
-
PDFDownload PDF ↗Reference – sitem-insel Bern, Switzerland