The Belimo 22DTM-1106 is an original Swiss-engineered HVAC component (Duct sensor CO₂ / Humidity / Temperature active, 0...5 V, 0...10 V, Probe length 180 mm, Probe diameter 19.5 mm, LCD) in the Belimo Duct Sensors (Air) series, designed for commercial building automation, hydronic control, and air-handling systems.
Key Technical Highlights:
- Voltage AC/DC: AC/DC 24 V
- Electrical connection: Terminals
- Measured values: CO₂, Temperature, Humidity
- Output signal: 0...5 V, 0...10 V
- Measuring range CO₂: Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm
Product Identification
- Brand: Belimo
- Part No. (SKU): 22DTM-1106
- Department: Sensors
- Category: Duct Sensors (Air)
- Warranty: 5 Years Standard Manufacturer Warranty
Commercial & Logistics Details
- List Price (MSRP): €659.00 (EXW)
- Trade Price: €461.30
- Manufacturer HQ: Switzerland (CH)
- Minimum Order Qty (MOQ): 1 pc(s)
- Sales Status: Saleable Product
Technical Specifications
| Voltage AC/DC | AC/DC 24 V |
| Electrical connection | Terminals |
| Measured values | CO₂, Temperature, Humidity |
| Output signal | 0...5 V, 0...10 V |
| Measuring range CO₂ | Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm |
| Measuring range humidity | 0...100% RH |
| Measuring range temperature | 0...50°C [32...122°F] |
| Output Voltage [Range] | 3 x 0...5 V, 0...10 V, min. resistance 10 kΩ |
| Output signal active note | Output 0...5/10 V with Jumper adjustable |
| Display type | LCD |
| Probe length | 180 mm |
Downloads & Technical Documentation
Belimo Official Portal ↗-
PDFDownload PDF ↗Technical data sheet – 22DTM-11..
-
PDFDownload PDF ↗Installation instructions – 22DC..-.. / 22DT..-..
-
PDFDownload PDF ↗Installation instructions – 22DC..-.. / 22DT..-.. flex conduit
-
PDFDownload PDF ↗EU Declaration of Conformity – 22DTM-1106
-
PDFDownload PDF ↗Environmental Declaration – 22DC../22DTC../22DTM../22DCV../22DCM../22DCK..
-
PDFDownload PDF ↗Brochure – Belimo sensors and meters
-
PDFDownload PDF ↗Flyer – CO2 measured values below 400 ppm - Error or reality ?
-
PDFDownload PDF ↗Manual – Sensor installation
-
PDFDownload PDF ↗Reference – AR Bygg, Sweden
-
PDFDownload PDF ↗Reference – Emch+Berger ImmoConsult AG, Switzerland
-
PDFDownload PDF ↗Reference – HUG AG, Switzerland
-
PDFDownload PDF ↗Reference – Hagl GmbH, Germany
-
PDFDownload PDF ↗Reference – High-rise building Tscharnergut Bern, Switzerland
-
PDFDownload PDF ↗Reference – Motta hut Lenzerheide, Switzerland
-
PDFDownload PDF ↗Reference – Phoenix Contact, Switzerland
-
PDFDownload PDF ↗Reference – Scott Sports Givisiez, Switzerland
-
PDFDownload PDF ↗Reference – Stadler Rail St. Margrethen, Switzerland
-
PDFDownload PDF ↗Reference – UTEK, Italy
-
PDFDownload PDF ↗Reference – University Hospital Zurich, Switzerland
-
PDFDownload PDF ↗Reference – sitem-insel Bern, Switzerland