Product Details & Technical Specifications
The Belimo 22DTM-15 is an original Swiss-engineered HVAC component (Duct sensor CO₂ / Humidity / Temperature active, Modbus, 0...5 V, 0...10 V, Probe length 180 mm, Probe diameter 19.5 mm) in the Belimo Bus & System Integration series, designed for commercial building automation, hydronic control, and air-handling systems.
Key Technical Highlights:
- Voltage AC/DC: AC/DC 24 V
- Electrical connection: Terminals
- Measured values: CO₂, Temperature, Humidity
- Output signal: Modbus, 0...5 V, 0...10 V
- Measuring range CO₂: Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm, Over Modbus: 0...10000 ppm
Product Identification
- Brand: Belimo
- Part No. (SKU): 22DTM-15
- Department: Meters
- Category: Bus & System Integration
- Warranty: 5 Years Standard Manufacturer Warranty
Commercial & Logistics Details
- List Price (MSRP): €599.00 (EXW)
- Trade Price: €419.30
- Manufacturer HQ: Switzerland (CH)
- Minimum Order Qty (MOQ): 1 pc(s)
- Sales Status: Saleable Product
Technical Specifications
| Voltage AC/DC | AC/DC 24 V |
| Electrical connection | Terminals |
| Measured values | CO₂, Temperature, Humidity |
| Output signal | Modbus, 0...5 V, 0...10 V |
| Measuring range CO₂ | Default setting: 0...2000 ppm, With A-22G-A05: 0...5000 ppm, Over Modbus: 0...10000 ppm |
| Measuring range humidity | Adjustable via Modbus, Default setting: 0...100% RH |
| Measuring range temperature | Adjustable via Modbus, 0...50°C [32...122°F] |
| Communication | Modbus RTU |
| Output Voltage [Range] | 2 x 0...5 V, 0...10 V, min. resistance 10 kΩ |
| Output signal active note | Output 0...5/10 V with Jumper adjustable |
| Probe length | 180 mm |
Downloads & Technical Documentation
Belimo Official Portal ↗-
PDFDownload PDF ↗Technical data sheet – 22DTM-15
-
PDFDownload PDF ↗Installation instructions – 22DTM-..5 / 22DTM-..6
-
PDFDownload PDF ↗Installation instructions – 22DTM-15 / 22DTM-16 flex conduit
-
PDFDownload PDF ↗EU Declaration of Conformity – 22DTM-15
-
PDFDownload PDF ↗Environmental Declaration – 22DC../22DTC../22DTM../22DCV../22DCM../22DCK..
-
PDFDownload PDF ↗Brochure – Belimo sensors and meters
-
PDFDownload PDF ↗Flyer – CO2 measured values below 400 ppm - Error or reality ?
-
PDFDownload PDF ↗Manual – Sensor installation
-
PDFDownload PDF ↗Modbus Interface description – Air quality sensors (for firmware version valid from 2022-05)
-
PDFDownload PDF ↗Modbus Interface desrciption – Sensors (for firmware version 4.2)
-
PDFDownload PDF ↗Reference – AR Bygg, Sweden
-
PDFDownload PDF ↗Reference – Emch+Berger ImmoConsult AG, Switzerland
-
PDFDownload PDF ↗Reference – HUG AG, Switzerland
-
PDFDownload PDF ↗Reference – Hagl GmbH, Germany
-
PDFDownload PDF ↗Reference – High-rise building Tscharnergut Bern, Switzerland
-
PDFDownload PDF ↗Reference – Motta hut Lenzerheide, Switzerland
-
PDFDownload PDF ↗Reference – Phoenix Contact, Switzerland
-
PDFDownload PDF ↗Reference – Scott Sports Givisiez, Switzerland
-
PDFDownload PDF ↗Reference – Stadler Rail St. Margrethen, Switzerland
-
PDFDownload PDF ↗Reference – UTEK, Italy
-
PDFDownload PDF ↗Reference – University Hospital Zurich, Switzerland
-
PDFDownload PDF ↗Reference – sitem-insel Bern, Switzerland