Skip to product information
1 of 1

Siemens

Siemens DXR2.E09-101A - Compact room automation station, BACnet/IP, 230 V, flat housing, 1 DI, 2 UI, 3 relay, 3 AO

Siemens DXR2.E09-101A - Compact room automation station, BACnet/IP, 230 V, flat housing, 1 DI, 2 UI, 3 relay, 3 AO

Part No: DXR2.E09-101A EAN: 7612914098627
Regular price €213,29
Sale price €213,29 Regular price €304,70
Ships in 3–5 business days
Quantity
Request a Quote
View full details

Product Details & Technical Specifications

The Siemens DXR2.E09-101A is a compact BACnet/IP room automation station engineered for decentralized terminal HVAC control and integrated room automation. Operating on direct 230 V AC line voltage, the unit features an integrated 2-port Ethernet switch and KNX PL-Link peripheral bus to execute synchronized climate control algorithms across VAV, fan-assisted, and hydronic terminal systems without requiring external 24 V step-down transformers.

Recommended Applications:
  • 2-pipe and 4-pipe fan coil units (FCUs) requiring direct 230 V fan stage switching and modulating 0...10 V valve actuation
  • Variable air volume (VAV) terminal boxes with electric reheaters, floating dampers, or perimeter hydronic heating
  • Chilled beam and radiant ceiling cooling/heating systems integrated with demand-controlled ventilation (DCV)
Key Engineering Highlights:
  • Direct 230 V AC Line Supply: Eliminates the cost and enclosure footprint of dedicated 24 V power supplies while directly switching line-voltage fan stages or auxiliary heaters via three 250 V / 4 A relay outputs.
  • Dual-Port BACnet/IP & KNX PL-Link: Integrated 2-port Ethernet switch enables daisy-chain network topology, paired with a powered KNX PL-Link bus for plug-and-play room operator units and smart sensors.
  • Precision Mixed I/O Architecture: Equipped with 2 universal inputs, 1 digital input, and 3 analog outputs (DC 0...10 V) for accurate closed-loop control of modulating actuators and ECM blowers.
  • Compact Flat Enclosure: Low-profile 112 x 165 x 49 mm form factor designed for direct damper shaft installation, front-mounting, or surface fitting inside shallow ceiling plenums.

Compatibility & Installation: Mounts directly to damper shafts or standard surface baseplates within IP20 enclosures; fully compatible with Siemens Desigo CC management stations, KNX PL-Link room units (QMX3 series), and standard 0...10 V valve/damper actuators.

Product Identification

  • Brand: Siemens
  • Product No. (ASN): DXR2.E09-101A
  • Stock No. (SSN): S55376-C110
  • GTIN / EAN: 7612914098627
  • Warranty: 24 Months

Commercial & Logistics Details

  • List Price (MSRP): €304.70
  • Price: €213.29
  • Net Weight: 0.306 kg (306 g)
  • Country of Origin: Switzerland (CH)
  • Customs HS Code: 85371091
  • Minimum Order Qty (MOQ): 1 pc(s)
  • Sales Status: Saleable Product

Technical Specifications

Operating voltage AC 195.5...253 V, 230 V
Frequency 50/60 Hz
Power consumption 24 VA
Communication BACnet/IP , KNX PL-Link , KNX S-Mode
Universal inputs, number 2
Digital inputs, number 1
Analog outputs, number 3
Analog output, signal DC 0...10 V
Analog output, current 1 mA
Relay outputs, number 3
Relay output, switching voltage 250 V
Relay output, switching current 4 (3)A
Mounting Inside rooms , Directly on the damper shaft , Front mounting
Degree of protection IP20
Dimensions (W x H x D) 112 x 165 x 49 mm

Downloads & Technical Documentation

Siemens HIT Official Portal ↗
  • PDF
    Datasheet: Compact room automation stations, BACnet/IP, AC 230 V, DXR2.E..
    View on Siemens HIT ↗
  • PDF
    Installation instruction: Desigo™ Room automation<BR/>Engineering, mounting and installation<BR/>PXC3.., DXR2.., DXR1..
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with variable fan, heating and cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with variable fan, heating/cooling coil (2 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with variable fan, 6-way heating/cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Hot water radiator on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Chilled ceiling on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Chilled ceiling with hot water radiator on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Chilled/heated ceiling (4 pipe) with 6 way valve on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Chilled/heated ceiling (2 pipe) with changeover on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with variable fan, heating and cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with variable fan, heating/cooling coil (2 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with variable fan, 6-way heating/cooling coil (4 pipe) on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Hot water radiator on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Chilled ceiling on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Chilled ceiling with hot water radiator on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Chilled/heated ceiling (4 pipe) with 6 way valve on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Chilled/heated ceiling (2 pipe) with changeover on analog output, DXR2.E09-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Passive chilled/heating beam (4 pipe) with 6-way valve on analog output
    View on Siemens HIT ↗
  • PDF
    Declarations and Certificates: Information about BT eu.bac certificates
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: EU Declaration of Conformity DXR2 (230Vac)
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: RCM Supplier's Declaration DXR2
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: BACnet Certificate DXR2.Exx-x, DXR2.Mxx-x, DXR2.E17C, DXR2.E17CX
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: UK Declaration of Conformity DXR2xxx.xxx
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: Compact room automation stations, DXR2.. 230V
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: Siemens EcoTech Profile - DXR2 PXC3
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: EPD Type II with LCA - Desigo - Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: EPD Type III - Desigo- Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
    View on Siemens HIT ↗
  • EXTERNAL
    CAD and BIM product data (PartCommunity): European portfolio: click here for further information
    View on Siemens HIT ↗
  • EXTERNAL
    CAD and BIM product data (PartCommunity): Asia/Pacific portfolio: click here for further information
    View on Siemens HIT ↗
  • DOC
    Dimension Drawings: Desigo Room Room Automation Station DXR2 – 2D Graphics<BR/>Desigo Room Room Automation Station DXR2 – 3D Graphics
    View on Siemens HIT ↗
  • EXTERNAL
    Operating Instructions: ABT Site BOS
    View on Siemens HIT ↗
  • PDF
    Operating Instructions: Web Interface
    View on Siemens HIT ↗
  • PDF
    Assortment / System Descriptions: DXR2, DXR1 Desigo Room Automation Range Description
    View on Siemens HIT ↗