Skip to product information
1 of 1

Siemens

Siemens DXR2.E10-101A - Compact room automation station, BACnet/IP, 230 V, flat housing, 1 DI, 2 UI, 3 relay, 4 triac

Siemens DXR2.E10-101A - Compact room automation station, BACnet/IP, 230 V, flat housing, 1 DI, 2 UI, 3 relay, 4 triac

Part No: DXR2.E10-101A EAN: 7612914098610
Regular price €213,29
Sale price €213,29 Regular price €304,70
Ships in 3–5 business days
Quantity
Request a Quote
View full details

Product Details & Technical Specifications

The Siemens DXR2.E10-101A is a compact, programmable room automation station engineered for standardized control of terminal HVAC equipment, lighting, and shading over native BACnet/IP. Operating directly on 230 V AC line voltage, the unit features an integrated dual-port Ethernet switch for cost-effective daisy-chain network topologies alongside an onboard KNX PL-Link bus for seamless connection to digital room operator units and multi-sensors. Its low-profile housing combines flexible universal inputs, triac switching, and high-capacity relays to handle distributed room control without requiring supplemental expansion modules or remote step-down transformers.

Recommended Applications:
  • 2-pipe and 4-pipe fan coil units (FCU) requiring multi-speed fan switching and thermal or motorized valve positioning
  • Variable air volume (VAV) and constant air volume (CAV) terminal boxes with direct-mount actuation or separate thermal reheat stages
  • Radiant panel ceiling heating and cooling systems integrated with decentralized room temperature and air quality monitoring
Key Engineering Highlights:
  • Line-Voltage Operation: Direct 230 V AC (195.5...253 V) mains power supply eliminates the need for external 24 V control transformers inside the local enclosure.
  • Optimized Terminal I/O Mix: Outfitted with 4 triac outputs (24 V AC, 0.15 A) for silent PWM or 3-point actuator control, 3 robust relay outputs (250 V, 4 A) for fan speeds or electric heaters, plus 2 universal inputs and 1 digital input.
  • High-Performance Connectivity: Onboard 2-port BACnet/IP switch facilitates daisy-chained Ethernet backbones, complemented by KNX PL-Link/S-Mode for automated bus-powered room sensor integration.
  • Compact Mechanical Profile: Measuring just 112 x 165 x 49 mm, the IP20 flat enclosure supports versatile mounting inside terminal units, on DIN rails, directly to damper shafts, or on front panels.

Compatibility & Installation: Mounts directly to damper shafts, flat surfaces, or inside control panels; seamlessly integrates into Siemens Desigo CC and third-party BACnet/IP building management systems via BTL-certified profiles.

Product Identification

  • Brand: Siemens
  • Product No. (ASN): DXR2.E10-101A
  • Stock No. (SSN): S55376-C109
  • GTIN / EAN: 7612914098610
  • Warranty: 24 Months

Commercial & Logistics Details

  • List Price (MSRP): €304.70
  • Price: €213.29
  • Net Weight: 0.306 kg (306 g)
  • Country of Origin: Switzerland (CH)
  • Customs HS Code: 85371091
  • Minimum Order Qty (MOQ): 1 pc(s)
  • Sales Status: Saleable Product

Technical Specifications

Operating voltage AC 195.5...253 V, 230 V
Frequency 50/60 Hz
Power consumption 24 VA
Communication BACnet/IP , KNX PL-Link , KNX S-Mode
Universal inputs, number 2
Digital inputs, number 1
Relay outputs, number 3
Relay output, switching voltage 250 V
Relay output, switching current 4 (3)A
Triac outputs, number 4
Triac output, switching voltage AC 24 V
Triac output, switching current 0.15 A
Mounting Inside rooms , Directly on the damper shaft , Front mounting
Degree of protection IP20
Dimensions (W x H x D) 112 x 165 x 49 mm

Downloads & Technical Documentation

Siemens HIT Official Portal ↗
  • PDF
    Datasheet: Compact room automation stations, BACnet/IP, AC 230 V, DXR2.E..
    View on Siemens HIT ↗
  • PDF
    Installation instruction: Desigo™ Room automation<BR/>Engineering, mounting and installation<BR/>PXC3.., DXR2.., DXR1..
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output, DXR2.E10-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater, DXR2.E10-101A
    View on Siemens HIT ↗
  • DOC
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation, DXR2.E10-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation, DXR2.E10-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output, DXR2.E10-101A
    View on Siemens HIT ↗
  • PDF
    Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater, DXR2.E10-101A
    View on Siemens HIT ↗
  • PDF
    Declarations and Certificates: Information about BT eu.bac certificates
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: EU Declaration of Conformity DXR2 (230Vac)
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: RCM Supplier's Declaration DXR2
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: BACnet Certificate DXR2.Exx-x, DXR2.Mxx-x, DXR2.E17C, DXR2.E17CX
    View on Siemens HIT ↗
  • PDF
    Declaration of conformity: UK Declaration of Conformity DXR2xxx.xxx
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: Compact room automation stations, DXR2.. 230V
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: Siemens EcoTech Profile - DXR2 PXC3
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: EPD Type II with LCA - Desigo - Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
    View on Siemens HIT ↗
  • PDF
    Environmental Documents: EPD Type III - Desigo- Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
    View on Siemens HIT ↗
  • EXTERNAL
    CAD and BIM product data (PartCommunity): European portfolio: click here for further information
    View on Siemens HIT ↗
  • EXTERNAL
    CAD and BIM product data (PartCommunity): Asia/Pacific portfolio: click here for further information
    View on Siemens HIT ↗
  • DOC
    Dimension Drawings: Desigo Room Room Automation Station DXR2 – 2D Graphics<BR/>Desigo Room Room Automation Station DXR2 – 3D Graphics
    View on Siemens HIT ↗
  • EXTERNAL
    Operating Instructions: ABT Site BOS
    View on Siemens HIT ↗
  • PDF
    Operating Instructions: Web Interface
    View on Siemens HIT ↗
  • PDF
    Assortment / System Descriptions: DXR2, DXR1 Desigo Room Automation Range Description
    View on Siemens HIT ↗