Product Details & Technical Specifications
The Siemens DXR2.E10-101A is a compact, programmable room automation station engineered for standardized control of terminal HVAC equipment, lighting, and shading over native BACnet/IP. Operating directly on 230 V AC line voltage, the unit features an integrated dual-port Ethernet switch for cost-effective daisy-chain network topologies alongside an onboard KNX PL-Link bus for seamless connection to digital room operator units and multi-sensors. Its low-profile housing combines flexible universal inputs, triac switching, and high-capacity relays to handle distributed room control without requiring supplemental expansion modules or remote step-down transformers.
- 2-pipe and 4-pipe fan coil units (FCU) requiring multi-speed fan switching and thermal or motorized valve positioning
- Variable air volume (VAV) and constant air volume (CAV) terminal boxes with direct-mount actuation or separate thermal reheat stages
- Radiant panel ceiling heating and cooling systems integrated with decentralized room temperature and air quality monitoring
- Line-Voltage Operation: Direct 230 V AC (195.5...253 V) mains power supply eliminates the need for external 24 V control transformers inside the local enclosure.
- Optimized Terminal I/O Mix: Outfitted with 4 triac outputs (24 V AC, 0.15 A) for silent PWM or 3-point actuator control, 3 robust relay outputs (250 V, 4 A) for fan speeds or electric heaters, plus 2 universal inputs and 1 digital input.
- High-Performance Connectivity: Onboard 2-port BACnet/IP switch facilitates daisy-chained Ethernet backbones, complemented by KNX PL-Link/S-Mode for automated bus-powered room sensor integration.
- Compact Mechanical Profile: Measuring just 112 x 165 x 49 mm, the IP20 flat enclosure supports versatile mounting inside terminal units, on DIN rails, directly to damper shafts, or on front panels.
Compatibility & Installation: Mounts directly to damper shafts, flat surfaces, or inside control panels; seamlessly integrates into Siemens Desigo CC and third-party BACnet/IP building management systems via BTL-certified profiles.
Product Identification
- Brand: Siemens
- Product No. (ASN): DXR2.E10-101A
- Stock No. (SSN): S55376-C109
- GTIN / EAN: 7612914098610
- Warranty: 24 Months
Commercial & Logistics Details
- List Price (MSRP): €304.70
- Price: €213.29
- Net Weight: 0.306 kg (306 g)
- Country of Origin: Switzerland (CH)
- Customs HS Code: 85371091
- Minimum Order Qty (MOQ): 1 pc(s)
- Sales Status: Saleable Product
Technical Specifications
| Operating voltage | AC 195.5...253 V, 230 V |
| Frequency | 50/60 Hz |
| Power consumption | 24 VA |
| Communication | BACnet/IP , KNX PL-Link , KNX S-Mode |
| Universal inputs, number | 2 |
| Digital inputs, number | 1 |
| Relay outputs, number | 3 |
| Relay output, switching voltage | 250 V |
| Relay output, switching current | 4 (3)A |
| Triac outputs, number | 4 |
| Triac output, switching voltage | AC 24 V |
| Triac output, switching current | 0.15 A |
| Mounting | Inside rooms , Directly on the damper shaft , Front mounting |
| Degree of protection | IP20 |
| Dimensions (W x H x D) | 112 x 165 x 49 mm |
Downloads & Technical Documentation
Siemens HIT Official Portal ↗-
PDFView on Siemens HIT ↗Datasheet: Compact room automation stations, BACnet/IP, AC 230 V, DXR2.E..
-
PDFView on Siemens HIT ↗Installation instruction: Desigo™ Room automation<BR/>Engineering, mounting and installation<BR/>PXC3.., DXR2.., DXR1..
-
DOCView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output, DXR2.E10-101A
-
DOCView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater, DXR2.E10-101A
-
DOCView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation, DXR2.E10-101A
-
PDFView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation, DXR2.E10-101A
-
PDFView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output, DXR2.E10-101A
-
PDFView on Siemens HIT ↗Application sheet: Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater, DXR2.E10-101A
-
PDFView on Siemens HIT ↗Declarations and Certificates: Information about BT eu.bac certificates
-
PDFView on Siemens HIT ↗Declaration of conformity: EU Declaration of Conformity DXR2 (230Vac)
-
PDFView on Siemens HIT ↗Declaration of conformity: RCM Supplier's Declaration DXR2
-
PDFView on Siemens HIT ↗Declaration of conformity: BACnet Certificate DXR2.Exx-x, DXR2.Mxx-x, DXR2.E17C, DXR2.E17CX
-
PDFView on Siemens HIT ↗Declaration of conformity: UK Declaration of Conformity DXR2xxx.xxx
-
PDFView on Siemens HIT ↗Environmental Documents: Compact room automation stations, DXR2.. 230V
-
PDFView on Siemens HIT ↗Environmental Documents: Siemens EcoTech Profile - DXR2 PXC3
-
PDFView on Siemens HIT ↗Environmental Documents: EPD Type II with LCA - Desigo - Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
-
PDFView on Siemens HIT ↗Environmental Documents: EPD Type III - Desigo- Building Automation - Automation stations PXC/DXR2, web interface PXG and edge devices CFG/CXG
-
EXTERNALView on Siemens HIT ↗CAD and BIM product data (PartCommunity): European portfolio: click here for further information
-
EXTERNALView on Siemens HIT ↗CAD and BIM product data (PartCommunity): Asia/Pacific portfolio: click here for further information
-
DOCView on Siemens HIT ↗Dimension Drawings: Desigo Room Room Automation Station DXR2 – 2D Graphics<BR/>Desigo Room Room Automation Station DXR2 – 3D Graphics
-
EXTERNALView on Siemens HIT ↗Operating Instructions: ABT Site BOS
-
PDFView on Siemens HIT ↗Operating Instructions: Web Interface
-
PDFView on Siemens HIT ↗Assortment / System Descriptions: DXR2, DXR1 Desigo Room Automation Range Description